{"id":5557,"date":"2015-05-29T00:00:32","date_gmt":"2015-05-29T05:00:32","guid":{"rendered":"http:\/\/krisbunda.com\/blog\/?p=5557"},"modified":"2016-02-27T22:53:53","modified_gmt":"2016-02-28T04:53:53","slug":"the-evolution-of-sump-lift-station-cover-design","status":"publish","type":"post","link":"https:\/\/krisbunda.com\/blog\/2015\/05\/29\/the-evolution-of-sump-lift-station-cover-design\/","title":{"rendered":"The Evolution of a Sump \/ Lift Station Cover Design"},"content":{"rendered":"<h3>Lift Station Explained<\/h3>\n<p>There&#8217;s a hole in my basement that the downstairs toilet, shower, sink, and washing machine empty into. There&#8217;s also a submersible pump in the hole which pushes all that stuff up a pipe, where it begins to slide down into a septic system. This hole is called a &#8220;Lift Station,&#8221;\u00a0and it \u00a0needs a pump because it&#8217;s actually below the grade of the septic tank.<\/p>\n<figure id=\"attachment_5571\" class=\"thumbnail wp-caption aligncenter\" style=\"width: 300px\"><a href=\"http:\/\/krisbunda.com\/blog\/2015\/05\/29\/the-evolution-of-sump-lift-station-cover-design\/bn270-zoeller-sewage-pump-01-01\/\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5571 size-full\" src=\"http:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/BN270-Zoeller-Sewage-Pump-01-01.jpg\" alt=\"Lift Station Sewage Pump (Do not aim directly at face)\" width=\"300\" height=\"300\" srcset=\"https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/BN270-Zoeller-Sewage-Pump-01-01.jpg 300w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/BN270-Zoeller-Sewage-Pump-01-01-150x150.jpg 150w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption class=\"caption wp-caption-text\">Lift Station Sewage Pump (Do not aim directly at face)<\/figcaption><\/figure>\n<p>The previous lid\u00a0for my lift station, probably the original installed about 30 years ago, had rusted to the point that it was literally more holes than lid. I&#8217;m not sure how thick the original steel was, but it was almost\u00a0an interesting case study in corrosion by the time I threw it away. And that meant I needed a new one. Allow me to walk you through the iterations of an afternoon of lid design.<\/p>\n<h3>Step 1: Half-Baked<\/h3>\n<p>In my experience, the first iteration of a new assembly design (not a revision) will have at least a major flaw or flaws that for some\u00a0reason were not apparent to the designer before first review. If you look at the lid assembly below, it has 2 holes, which sounds good as far as lift stations go, but one of those holes is actually for a rubber stopper with a cord hole to plug the pump into the wall. So there&#8217;s really only one hole to run 1.5&#8243; PVC piping out of (for the pump to send up liquids and sewage). In other words, no vent outlet.<\/p>\n<p>What&#8217;s the problem? Well, there are all sorts of smelly gasses that want to belch out of a lift station, and you might as well give them somewhere to go other than inside your house. Seal the crock airtight, and make a route to pipe them to outdoors.<\/p>\n<p>Unfortunately, the original installer never ran a vent pipe, which is probably why I didn&#8217;t account for one initially.<\/p>\n<figure id=\"attachment_5575\" class=\"thumbnail wp-caption aligncenter\" style=\"width: 462px\"><a href=\"http:\/\/krisbunda.com\/blog\/2015\/05\/29\/the-evolution-of-sump-lift-station-cover-design\/lift-station-cover-vsn1a-2\/\" rel=\"attachment wp-att-5574\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5575 size-large\" src=\"http:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN1A1-462x600.png\" alt=\"LIFT STATION COVER DESIGN - VSN1\" width=\"462\" height=\"600\" srcset=\"https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN1A1-462x600.png 462w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN1A1-115x150.png 115w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN1A1-231x300.png 231w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN1A1.png 768w\" sizes=\"auto, (max-width: 462px) 100vw, 462px\" \/><\/a><figcaption class=\"caption wp-caption-text\">LIFT STATION COVER DESIGN &#8211; VSN1<\/figcaption><\/figure>\n<h3>Step 2: More Holes<\/h3>\n<p>I added another hole. Of course, that means changing everything and it&#8217;s never just as simple as &#8220;add another hole&#8221;.<\/p>\n<p>BTW, if it&#8217;s not completely obvious, do you understand why there&#8217;re 3 plate pieces to this lid? It&#8217;s so the lid can be removed w\/out having to remove the pipes. You&#8217;ll still have to break the caulk seal between the lid assembly and the basement floor though, since it&#8217;s not a bolt-on lid.<\/p>\n<figure id=\"attachment_5576\" class=\"thumbnail wp-caption aligncenter\" style=\"width: 464px\"><a href=\"http:\/\/krisbunda.com\/blog\/2015\/05\/29\/the-evolution-of-sump-lift-station-cover-design\/lift-station-cover-vsn2a\/\" rel=\"attachment wp-att-5576\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5576 size-large\" src=\"http:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN2A-464x600.png\" alt=\"LIFT STATION COVER - VSN2\" width=\"464\" height=\"600\" srcset=\"https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN2A-464x600.png 464w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN2A-116x150.png 116w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN2A-232x300.png 232w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN2A.png 484w\" sizes=\"auto, (max-width: 464px) 100vw, 464px\" \/><\/a><figcaption class=\"caption wp-caption-text\">LIFT STATION COVER &#8211; VSN2 (Notice every plate part is changed)<\/figcaption><\/figure>\n<h3>Step 3: Source Special Parts<\/h3>\n<p>I had a surprisingly difficult time tracking down the plastic pipe flange parts that I could purchase separately for this project (as opposed to kitted with an expensive lid assembly). Apparently they&#8217;re a specialty item, or I&#8217;m just bad at Googling. I found some 2D prints of some flanges online first, and then later finally found a distributor of the product that didn&#8217;t only sell to plumbers or contractors.<\/p>\n<figure id=\"attachment_5577\" class=\"thumbnail wp-caption aligncenter\" style=\"width: 462px\"><a href=\"http:\/\/krisbunda.com\/blog\/2015\/05\/29\/the-evolution-of-sump-lift-station-cover-design\/topp-incorporated-pipe-flanges-for-sump-covers\/\" rel=\"attachment wp-att-5577\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5577 size-large\" src=\"http:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/TOPP-INCORPORATED-PIPE-FLANGES-FOR-SUMP-COVERS-462x600.png\" alt=\"TOPP INCORPORATED PIPE FLANGES FOR SUMP COVERS\" width=\"462\" height=\"600\" srcset=\"https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/TOPP-INCORPORATED-PIPE-FLANGES-FOR-SUMP-COVERS-462x600.png 462w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/TOPP-INCORPORATED-PIPE-FLANGES-FOR-SUMP-COVERS-116x150.png 116w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/TOPP-INCORPORATED-PIPE-FLANGES-FOR-SUMP-COVERS-231x300.png 231w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/TOPP-INCORPORATED-PIPE-FLANGES-FOR-SUMP-COVERS.png 708w\" sizes=\"auto, (max-width: 462px) 100vw, 462px\" \/><\/a><figcaption class=\"caption wp-caption-text\">TOPP INCORPORATED PIPE FLANGES FOR SUMP COVERS<\/figcaption><\/figure>\n<p>I used the DXF from the manufacturer to make 3D models of the flanges to ensure proper fit up.<\/p>\n<figure id=\"attachment_5578\" class=\"thumbnail wp-caption aligncenter\" style=\"width: 463px\"><a href=\"http:\/\/krisbunda.com\/blog\/2015\/05\/29\/the-evolution-of-sump-lift-station-cover-design\/lift-station-cover-vsn3a\/\" rel=\"attachment wp-att-5578\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5578 size-large\" src=\"http:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN3A-463x600.png\" alt=\"LIFT STATION COVER - VSN3A - ASSEMBLY WITH PLASTIC PIPE FLANGE PARTS\" width=\"463\" height=\"600\" srcset=\"https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN3A-463x600.png 463w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN3A-116x150.png 116w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN3A-231x300.png 231w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN3A-560x726.png 560w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN3A.png 716w\" sizes=\"auto, (max-width: 463px) 100vw, 463px\" \/><\/a><figcaption class=\"caption wp-caption-text\">LIFT STATION COVER &#8211; VSN3A &#8211; ASSEMBLY WITH PLASTIC PIPE FLANGE PARTS<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_5579\" class=\"thumbnail wp-caption aligncenter\" style=\"width: 595px\"><a href=\"http:\/\/krisbunda.com\/blog\/2015\/05\/29\/the-evolution-of-sump-lift-station-cover-design\/lift-station-cover-vsn3b\/\" rel=\"attachment wp-att-5579\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5579 size-large\" src=\"http:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN3B-600x463.png\" alt=\"LIFT STATION COVER - VSN3B - SHEET METAL JOG BEND\" width=\"595\" height=\"459\" srcset=\"https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN3B-600x463.png 600w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN3B-150x116.png 150w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN3B-300x231.png 300w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN3B.png 1188w\" sizes=\"auto, (max-width: 595px) 100vw, 595px\" \/><\/a><figcaption class=\"caption wp-caption-text\">LIFT STATION COVER &#8211; VSN3B &#8211; SHEET METAL JOG BEND<\/figcaption><\/figure>\n<h3>Step 4: Improvise<\/h3>\n<p>Later we realized it was going to be too difficult to make this severe jog bend, so the fabricator decided on the fly to just cut the part where the offset bend was to be and weld it back together (still creating a 1\/8th jog because that&#8217;s approx. how thick the plate is.<\/p>\n<figure id=\"attachment_5586\" class=\"thumbnail wp-caption aligncenter\" style=\"width: 460px\"><a href=\"http:\/\/krisbunda.com\/blog\/2015\/05\/29\/the-evolution-of-sump-lift-station-cover-design\/lift-station-cover-vsn4-2\/\" rel=\"attachment wp-att-5580\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5586 size-large\" src=\"http:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN41-460x600.png\" alt=\"LIFT STATION COVER - VSN4 - CUT APART AND WELDED FOR OFFSET\" width=\"460\" height=\"600\" srcset=\"https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN41-460x600.png 460w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN41-115x150.png 115w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN41-230x300.png 230w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/LIFT-STATION-COVER-VSN41.png 770w\" sizes=\"auto, (max-width: 460px) 100vw, 460px\" \/><\/a><figcaption class=\"caption wp-caption-text\">LIFT STATION COVER &#8211; VSN4 &#8211; CUT APART AND WELDED FOR OFFSET<\/figcaption><\/figure>\n<p>The welding warped it a little, but it still got powder coated and installed (caulked in place to create a seal). Works great.<\/p>\n<h3>Hardware &amp; Gasket<\/h3>\n<p>The bolts are zinc plated hex cap 3\/8&#8243; with matched gasket washers&#8211;they&#8217;re used to screw grain bin sheets together, and come by the bucketload when you order a new grain bin. I also used some of the caulk-on-a-roll to seal the lid to the concrete&#8211;picture a thick bead of caulk that stays sticky and pliable on top of a long strip of wax paper, rolled up in a big round disk&#8211;it&#8217;s actually pretty handy for the application of sealing overlapping grain bin sheet seams.<\/p>\n<figure id=\"attachment_5573\" class=\"thumbnail wp-caption aligncenter\" style=\"width: 595px\"><a href=\"http:\/\/krisbunda.com\/blog\/2015\/05\/29\/the-evolution-of-sump-lift-station-cover-design\/custom-lift-station-cover-and-pipe-flange-hardware-assembly-cad-screenshot\/\" rel=\"attachment wp-att-5573\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5573 size-large\" src=\"http:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/CUSTOM-LIFT-STATION-COVER-AND-PIPE-FLANGE-HARDWARE-ASSEMBLY-CAD-SCREENSHOT-600x445.png\" alt=\"CUSTOM LIFT STATION COVER AND PIPE FLANGE HARDWARE ASSEMBLY (CAD SCREENSHOT)\" width=\"595\" height=\"441\" srcset=\"https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/CUSTOM-LIFT-STATION-COVER-AND-PIPE-FLANGE-HARDWARE-ASSEMBLY-CAD-SCREENSHOT-600x445.png 600w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/CUSTOM-LIFT-STATION-COVER-AND-PIPE-FLANGE-HARDWARE-ASSEMBLY-CAD-SCREENSHOT-150x111.png 150w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/CUSTOM-LIFT-STATION-COVER-AND-PIPE-FLANGE-HARDWARE-ASSEMBLY-CAD-SCREENSHOT-300x222.png 300w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/CUSTOM-LIFT-STATION-COVER-AND-PIPE-FLANGE-HARDWARE-ASSEMBLY-CAD-SCREENSHOT-848x628.png 848w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/CUSTOM-LIFT-STATION-COVER-AND-PIPE-FLANGE-HARDWARE-ASSEMBLY-CAD-SCREENSHOT-730x542.png 730w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/CUSTOM-LIFT-STATION-COVER-AND-PIPE-FLANGE-HARDWARE-ASSEMBLY-CAD-SCREENSHOT-365x271.png 365w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/CUSTOM-LIFT-STATION-COVER-AND-PIPE-FLANGE-HARDWARE-ASSEMBLY-CAD-SCREENSHOT-560x415.png 560w, https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/CUSTOM-LIFT-STATION-COVER-AND-PIPE-FLANGE-HARDWARE-ASSEMBLY-CAD-SCREENSHOT.png 989w\" sizes=\"auto, (max-width: 595px) 100vw, 595px\" \/><\/a><figcaption class=\"caption wp-caption-text\">CUSTOM LIFT STATION COVER AND PIPE FLANGE HARDWARE ASSEMBLY (CAD SCREENSHOT)<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Watch a product design become more appropriate for its intent through iterations (lift station \/ sump hole lid assembly with flanges).<\/p>\n","protected":false},"author":1,"featured_media":5573,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_editorskit_title_hidden":false,"_editorskit_reading_time":0,"_editorskit_is_block_options_detached":false,"_editorskit_block_options_position":"{}","inline_featured_image":false,"kt_blocks_editor_width":"","_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[4],"tags":[45,560,166,163,135,563,171,161,257,271,200,145,168],"class_list":["post-5557","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-designer","tag-basement-remodel","tag-cad","tag-custom","tag-design","tag-diy","tag-drawing","tag-fabrication","tag-home","tag-home-improvement","tag-plumbing","tag-septic","tag-solidworks","tag-steel"],"aioseo_notices":[],"jetpack_publicize_connections":[],"taxonomy_info":{"category":[{"value":4,"label":"Designer"}],"post_tag":[{"value":45,"label":"basement remodel"},{"value":560,"label":"CAD"},{"value":166,"label":"custom"},{"value":163,"label":"design"},{"value":135,"label":"DIY"},{"value":563,"label":"drawing"},{"value":171,"label":"fabrication"},{"value":161,"label":"home"},{"value":257,"label":"home improvement"},{"value":271,"label":"plumbing"},{"value":200,"label":"Septic"},{"value":145,"label":"SolidWorks"},{"value":168,"label":"steel"}]},"featured_image_src_large":["https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/CUSTOM-LIFT-STATION-COVER-AND-PIPE-FLANGE-HARDWARE-ASSEMBLY-CAD-SCREENSHOT-600x445.png",600,445,true],"author_info":{"display_name":"Kris Bunda","author_link":"https:\/\/krisbunda.com\/blog\/author\/kris-bunda\/"},"comment_info":0,"category_info":[{"term_id":4,"name":"Designer","slug":"designer","term_group":0,"term_taxonomy_id":4,"taxonomy":"category","description":"Posts focusing on web, graphic, CAD, and other design.","parent":0,"count":91,"filter":"raw","cat_ID":4,"category_count":91,"category_description":"Posts focusing on web, graphic, CAD, and other design.","cat_name":"Designer","category_nicename":"designer","category_parent":0}],"tag_info":[{"term_id":45,"name":"basement remodel","slug":"basement-remodel","term_group":0,"term_taxonomy_id":45,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw"},{"term_id":560,"name":"CAD","slug":"cad","term_group":0,"term_taxonomy_id":33,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"},{"term_id":166,"name":"custom","slug":"custom","term_group":0,"term_taxonomy_id":166,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"},{"term_id":163,"name":"design","slug":"design","term_group":0,"term_taxonomy_id":163,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"},{"term_id":135,"name":"DIY","slug":"diy","term_group":0,"term_taxonomy_id":135,"taxonomy":"post_tag","description":"","parent":0,"count":26,"filter":"raw"},{"term_id":563,"name":"drawing","slug":"drawing","term_group":0,"term_taxonomy_id":503,"taxonomy":"post_tag","description":"Technical drawings, Illustrated Instructions, Schematics, or By-hand drawings","parent":0,"count":28,"filter":"raw"},{"term_id":171,"name":"fabrication","slug":"fabrication","term_group":0,"term_taxonomy_id":171,"taxonomy":"post_tag","description":"","parent":0,"count":26,"filter":"raw"},{"term_id":161,"name":"home","slug":"home","term_group":0,"term_taxonomy_id":161,"taxonomy":"post_tag","description":"","parent":0,"count":23,"filter":"raw"},{"term_id":257,"name":"home improvement","slug":"home-improvement","term_group":0,"term_taxonomy_id":257,"taxonomy":"post_tag","description":"","parent":0,"count":13,"filter":"raw"},{"term_id":271,"name":"plumbing","slug":"plumbing","term_group":0,"term_taxonomy_id":271,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":200,"name":"Septic","slug":"septic","term_group":0,"term_taxonomy_id":200,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":145,"name":"SolidWorks","slug":"solidworks","term_group":0,"term_taxonomy_id":145,"taxonomy":"post_tag","description":"","parent":0,"count":34,"filter":"raw"},{"term_id":168,"name":"steel","slug":"steel","term_group":0,"term_taxonomy_id":168,"taxonomy":"post_tag","description":"","parent":0,"count":26,"filter":"raw"}],"jetpack_featured_media_url":"https:\/\/krisbunda.com\/blog\/wp-content\/uploads\/2015\/05\/CUSTOM-LIFT-STATION-COVER-AND-PIPE-FLANGE-HARDWARE-ASSEMBLY-CAD-SCREENSHOT.png","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p1NcZe-1rD","amp_enabled":true,"_links":{"self":[{"href":"https:\/\/krisbunda.com\/blog\/wp-json\/wp\/v2\/posts\/5557","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/krisbunda.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/krisbunda.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/krisbunda.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/krisbunda.com\/blog\/wp-json\/wp\/v2\/comments?post=5557"}],"version-history":[{"count":0,"href":"https:\/\/krisbunda.com\/blog\/wp-json\/wp\/v2\/posts\/5557\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/krisbunda.com\/blog\/wp-json\/wp\/v2\/media\/5573"}],"wp:attachment":[{"href":"https:\/\/krisbunda.com\/blog\/wp-json\/wp\/v2\/media?parent=5557"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/krisbunda.com\/blog\/wp-json\/wp\/v2\/categories?post=5557"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/krisbunda.com\/blog\/wp-json\/wp\/v2\/tags?post=5557"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}